490*220MM Anti-cracking IP66/IP67/IP68 with PLC splitter Waterproof Splice Boc
Product Description
The enclosure casing is made of quality engineering plastics, and of good performance of anti-erosion against acid and alkali salt, anti-aging, as well as smooth appearance and reliable mechanical structure.
The mechanical structure is reliable and has the performance of resisting wild environment and intensive climate changes and serious working environment.
The protection grade reaches IP66.
The closures are applicable to ribbon type optical cable and common optical cable.
The splice trays inside the closure are turn-able like booklets, and have adequate curvature radius and space for winding optical fiber to make sure the curvature radius for optical winding 40mm.
Each optical cable and fiber can be operated individually.
The closure is of small volume, big capacity and convenient maintenance.
The elastic rubber seal rings inside the closure are of good sealing and sweat-proof performance. The casing can be opened repeatedly without air leakage. No special tools are required.
The operation is easy and simple. The air valve is provided for the closure and used to check the sealing performance.
Dimensions and Capability:
Dimensions ( L*W*H): 490mm*220mm
Maximum Capacity: Bundle - 240 Cores
Cable Entrances: 1 In 4Out
Diameter of Cable: Φ5mm - Φ35mm.
Sealing Method:Mechanical
Operation conditions:
Temperatures: -40ºC~+60ºC
Humidity: ≤95% (at 40ºC)
Air Pressure: 70kPa ~106kPa
Technical Specifications:
Seal performance: after the box is sealed, inflate to 100kPa inwards (inflation only apply to the models with the air hole), and then soak it in the water of normal temperature, after 15 minutes of steady observation, there is no bubble to overflow.
Insulation resistance: the insulation resistance between the metal work piece and the earth is greater than 20kMΩ.
Pressurization: there is no breakdown or flashover under 15kVdc/1min between the metal work piece and the earth.
The curvature radius of the fiber 40mm, without extra loss inside the splice tray.
It can bear the axial tensile strength no less than 1000N.
Lifetime: 25 years.
Other performances are all in accordance with the requirement of standard YD/T814-1998.
Fiber Optic Splitter box
Ordering Informaiton
Optical Splice Tray
Accessories
Packaging Size
Each Closure have individual box Size:22*21.5*49(cm)
6 pcs closure packed into one out carton box Size:70*44*52(cm)
Waterproof Joint Closures wall mount
Ordering Information
Optical Splice Trays
Accessories
Packaging Size
Each Closure have individual box Size:22*21.5*49(cm)
6 pcs closure packed into one out carton box Size:70*44*52(cm)
Main components
Name of components |
Quantity |
Usage |
Remarks |
FOSC cover |
1 piece |
Protecting fiber cable splices in whole |
Height x Diameter 400mm x 220mm |
Fiber optic splice tray (FOST) |
Max.:5 trays (bunchy) Max.: 5 trays (ribbon) |
Fixing heat shrinkable protective sleeve and holding fibers |
Suitable for: Bunchy: 48(cores) Ribbon: 24 (pieces) |
Base |
1set |
Fixing internal and external structure |
|
Plastic hoop |
1 set |
Fixing between FOSC cover and base |
|
Seal fitting |
1 piece |
Sealing between FOSC cover and base |
|
Pressure testing valve |
1 set |
After inject air, it is used for pressure testing and sealing testing |
Configuration as per requirement |
Earthing deriving device |
1 set |
Deriving metal parts of fiber cables in FOSC for earthing connection |
Configuration as per requirement
|
Testing Reports
Requirements |
Results |
Tightness testing |
Follow the standards:
IEC 61300-2-38 Method A IEC 60068-2-17 Test Qc No leakage under testing condition: Pressures: (40 ± 2) kPa Temperature: (23 ± 3) °C Testing duration: 15 minutes Testing deepness: place the whole closure into water. |
Hoarfrost testing |
Follow the standards:
IEC 61300-2-26 Method A IEC 60068-2-11 Test Ka Ensuring no leakage and the cover of closure is not broken, color is not changed, eroded under testing condition: Pressures: 0 kPa Temperature: (35 ± 2) °C Testing duration: 5 days Place closure in the water environment with NaCl's concentration of 5%. |
Drop testing |
Follow the standards:
IEC 61300-2-10 Method A Ensuring no leakage under testing condition: Drop length: 75cm Temperature: (45 ± 2) °C Drop count: 1 time |
Vibration testing |
Follow the standards:
IEC 61300-2-1 IEC 60068-2-6 Test Fc Ensuring no leakage under testing condition: Vibration frequency: 10 Hz. Amplitude: ≥ 6 mm (peak to peak) Testing duration: 28 hours |
Other requirement |
Can install splitters to the closure (if there is special requirement). For some small capacity closure (under 48 cores) used for Branching to subscribers can require for ODF mini and integrate splitters inside. The closure cover can sustain affect of ultraviolet ray without broken or changing color. Working temperature: (0 - 60) °C Humidity: 100% |