Customization: | Available |
---|---|
Application: | Communication |
Type: | Single-mode Fiber |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ADSS (All-Dielectric Self-Supporting) cable is ideal forinstallation in distribution as well as transmission environments, even when live-line installations are required.
Features
Can be installed without shutting offthe power.
ExcellentAT performance. The maximum inductive at the operating point ofAT jacket can reach 25kV.
Light weight and small diameter reducing the load caused by ice and wind and the load on towers and backprops.
Large span lengths and the largest span is over 200m.
Good performance oftensile strength and temperature.
The design life span is over 30 years.
Applications
Aerial
Structure and Technical Specifications ADSS-SJ(50-150M)
Ref. Outer |
Ref. Weight |
Rec. Daily Max. (kN) |
Max Allowable |
Break Strength (kN) |
Strength Member CSA (mm2) |
Modulus of (kN/mm2) |
Heat Expansion Coefficient (x10- 6/K) |
Suitable Span |
||||
PE Jacket |
AT Jacket |
A |
B |
C |
D |
|||||||
11 |
110 |
120 |
1.0 |
2.5 |
8 |
3.0 |
6.6 |
2.1 |
120 |
80 |
100 |
80 |
11.5 |
115 |
125 |
1.5 |
4 |
10 |
4.5 |
7.3 |
1.8 |
180 |
120 |
150 |
120 |
12 |
120 |
130 |
2.5 |
6 |
15 |
7.5 |
8.3 |
1.5 |
250 |
150 |
290 |
150 |
Structure and Technical Specifications ADSS-DJ(50-750M)
Ref. Outer |
Ref. Weight |
Rec. Daily Max. (kN) |
Max Allowable |
Break Strength (kN) |
Strength Member CSA (mm2) |
Modulus of (kN/mm2) |
Heat Expansion Coefficient (x10- 6/K) |
Suitable Span |
||||
PE Jacket |
AT Jacket |
A |
B |
C |
D |
|||||||
12.5 |
125 |
136 |
1.5 |
4 |
10 |
4.6 |
7.6 |
1.8 |
160 |
100 |
140 |
100 |
13.0 |
132 |
142 |
2.25 |
6 |
15 |
7.6 |
8.3 |
1.5 |
230 |
150 |
200 |
150 |
13.3 |
137 |
148 |
3.0 |
8 |
20 |
10.35 |
9.45 |
1.3 |
300 |
200 |
290 |
200 |
13.6 |
145 |
156 |
3.6 |
10 |
24 |
13.8 |
10.8 |
1.2 |
370 |
250 |
350 |
250 |
13.8 |
147 |
159 |
4.5 |
12 |
30 |
14.3 |
11.8 |
1.0 |
420 |
280 |
400 |
280 |
14.5 |
164 |
177 |
5.4 |
15 |
36 |
18.4 |
13.6 |
0.9 |
480 |
320 |
460 |
320 |
14.9 |
171 |
185 |
6.75 |
18 |
45 |
22.0 |
16.4 |
0.6 |
570 |
380 |
550 |
380 |
15.1 |
179 |
193 |
7.95 |
22 |
53 |
26.4 |
18.0 |
0.3 |
670 |
460 |
650 |
460 |
15.5 |
190 |
204 |
9.0 |
26 |
60 |
32.2 |
19.1 |
0.1 |
750 |
530 |
750 |
510 |
Note: Only a part of ADSS cables are listed in the table. ADSS cables with other spans can be inquired
from EFON directly.
Specifications in the table are got on condition that there is no height difference and the installation
sag is 1 %.
Fiber count is 2 to 72. The identification of fibers complies with the national standard.
This datasheet can only be a reference, but not a supplement to the contract. Please contact our
sales people for more detailed information.
You May Like
You May Need : Cable Fitting for ADSS Cable
Payment
For large orders, T/T , L/C, and E-credit lines are all offered.
For small orders, credit-cards are accepted.
Shipping & Delivery
We will send the products within 10 days.
We ship small batched by air, or large orders by container.
Return and Warranty:
All products have been tested before ship out
All products have 5 years warranty. If there is no man-made problem ,we will replace or repair for you freely.
We own the best after-sale service. If any problems happen ,our team will do our best to solve for customers.