ADSS All-Dielectric non-metallic Outdoor ADSS cable / ADSS Fiber Optic Cable
Product Description
ADSS fiber optic cable 's loose tubes are made of high modulus plastics (PBT) and filled with a water resistant filling gel. Loose tubes are stranded around the non-metallic central strength member (FRP), cable core is filled with cable filling compound. Polyethylene (PE) extruded as inner sheath, and then aramid yarns or glass yarns are applied over inner sheath to enhance tensile strength for special application. The cable is completed with PE outer sheath.
ADSS CABLE Feature
High quality optical fiber provides good transmission performance
Accurate fiber excess length control ensures excellent mechanical and temperature performance
Special filling gel filled loose tubes provide perfect optical fiber protection
All section water blocking present reliable performance of moisture-proof and water block
High Young's modulus fiber reinforced plastic (FRP) as central strength member gives high tensile strength
All dielectric structure,light weight, easy installation, good electromagnetic resistance, suitable for operating in electrical system or frequently lighting areas
Strict craft and raw material enable lifespan over 30 years
ADSS CABLE Performance
Application: Aerial
Operating temperature: -30~+70°C
Bending radius: Static 10×D : Dynamic 20×D
ADSS fiber optic cable
Application
Erect on the same pole with power line in new and old power line.
A long span
Areas of strong electric field, multi-thunder, etc
Products Standard:
Mechanical Performance :
Max Tension Performance : IEC 60794-1-2-E
Max. Operation Tension : IEC 60794-1-2-E1
Crush Test : IEC 6079 -1-2-E3
Impact Test : IEC 60794-1-2-E4
Repeated Bending : IEC 60794-1-2-E6
Torsion Test : IEC 60794-1-2-E7
Cable bend : IEC 60794-1-2-E11A
Attenuation Coefficient : ITU-T G.652
Structural Test : IEC-60793-1-20
Environmental Performance
Temperature Cycling : IEC 60794-1-2-F1
Water Penetration : IEC 60794-1-2-F5B
Filing Compound Flow : IEC 60794-1-E14
Structrure and Technical Specifications
Fiber Count |
Nominal Diameter (mm) |
Nominal Weight (kg/km) |
Max Fibers per Tube |
No. of (Tubes+fillers) |
Allowable Tensile Load (N) |
Allowable Crush Resistance (N/100mm) |
Short Term |
Long Term |
Short Term |
Long Term |
2 ~36 |
12.1 |
125 |
6 |
6 |
3000 |
1000 |
3000 |
1000 |
36 ~72 |
13.9 |
135 |
12 |
6 |
3000 |
1000 |
3000 |
1000 |
74 ~96 |
16.0 |
170 |
12 |
8 |
3000 |
1000 |
3000 |
1000 |
98 ~120 |
16.6 |
210 |
12 |
10 |
3000 |
1000 |
3000 |
1000 |
122 ~144 |
18.2 |
245 |
12 |
12 |
3000 |
1000 |
3000 |
1000 |
144 ~216 |
18.3 |
250 |
12 |
18 (2 layers) |
3000 |
1000 |
3000 |
1000 |
>216 |
Available upon customer's request |