Description
GYFTY 12 core fiber optic cable is an outdoor communication optical cable of non-metallic strength member of the loose tube jelly-filled structure, with polyethylene sheath.
Features and benefits:
Full cross-section water-blocking structure to ensure good water blocking and moisture resistance
Loose tube is filled with special ointment for a key fiber protection
High-modulus glassfibre reinforced plastics (FRP) central strength member
With all-dielectric (non-metallic) structure, and light weight, the fiber is convenient for laying, excellent in anti-electromagnetic capacity, and applicable to power system and multithunder area.
Product life of 30 years
Performance
Applications: Suitable for long-distance communication and indoor communication
Way of laying: Aerial , Duct
Operating temperature: -40 ~ + 70 °C
Bend radius: static 10x cable diameter :Dynamic 20x cable diameter
Sheath marking
The color of marking is white, but if the remarking is necessary, the white color marking shall be printed newly on a different position.
An occasional unclear of length marking is permitted if both of the neighboring markings are clear.
The both cable ends are sealed with heat shrinkable end caps to prevent water ingress
Applications:
Long distance communication system,
Local area network system
Subscriber network system
Installation method:
Aerial, duct
Technical parameters
Products Standard
Mechanical Performance :
Max Tension Performance : IEC 60794-1-2-E
Max. Operation Tension : IEC 60794-1-2-E1
Crush Test : IEC 6079 -1-2-E3
Impact Test : IEC 60794-1-2-E4
Repeated Bending : IEC 60794-1-2-E6
Torsion Test : IEC 60794-1-2-E7
Cable bend : IEC 60794-1-2-E11A
Attenuation Coefficient : ITU-T G.652
Structural Test : IEC-60793-1-20
Environmental Performance
Temperature Cycling : IEC 60794-1-2-F1
Water Penetration : IEC 60794-1-2-F5B
Filing Compound Flow : IEC 60794-1-E14
Structure and Technical Specifications
Fiber Count |
Nominal Diameter (mm) |
Nominal Weight (kg/km) |
Max Fibers per Tube |
No. of (Tubes+fillers) |
Allowable Tensile Load (N) |
Allowable Crush Resistance (N/100mm) |
Short Term |
Long Term |
Short Term |
Long Term |
2 ~36 |
10.2 |
85 |
6 |
6 |
1500 |
600 |
1000 |
300 |
36 ~72 |
11.1 |
100 |
12 |
6 |
1500 |
600 |
1000 |
300 |
74 ~96 |
12.6 |
130 |
12 |
8 |
1500 |
600 |
1000 |
300 |
98 ~120 |
14.1 |
162 |
12 |
10 |
1500 |
600 |
1000 |
300 |
122 ~144 |
15.9 |
204 |
12 |
12 |
1800 |
600 |
1000 |
300 |
144 ~216 |
15.9 |
205 |
12 |
18 (2 layers) |
2200 |
600 |
1000 |
300 |
> 216 |
Available upon customer ' s request |