Performance
GYTA33 is an outdoor communication optical cable of metallic strength member of the loose tube jelly-filled structure, with Al-polyethylene laminated sheath and single-layer thin round steel wire armored polyethylene outer sheath.
The loose tubes are made of high modulus plastics (PBT) and filled withwater resistant filling gel. Loose tubes are stranded around the metallic central strength member, cable core is filled with cable filling compound. The corrugated aluminum tape is longitudinally applied over the cable core, and combined with polyethylene (PE) inner sheath. Galvanized steel wires are stranded around inner sheath, and then extruded with PE outer sheath.
Feature
1, High quality optical fiber provides good transmission performance
2, Accurate fiber excess length control ensures excellent mechanical and temperature performance
3, Special filling gel filled loose tubes provide perfect optical fiber protection
4,All section water blocking ensure the cable core reliable performance of moisture-proof and water block
5, Corrosion resistance phosphated steel wire with high Young's modulus as central strength member givesdesirable tensile strength
6, Longitudinally Armor with both side coated aluminum tape and stranded steel wires armoring meet therequirements of high crush resistance, tensile strength, bulletproof property, heavy duty direct buryunderwater installation
7, Strict craft and raw material control enable lifespan over 30 years
Performance
Applications: Long-distance communication and indoor communication
Way of laying: Direct burial, underwater laying
Operating temperature: -40 ~ + 70 ° C
Bend radius: Static 15x cable diameter
Dynamic 30x cable diameter
Mechanical Performance:
Max Tension Performance: IEC 60794-1-2-E
Max. Operation Tension: IEC 60794-1-2-E1
Crush Test: IEC 6079 -1-2-E3
Impact Test: IEC 60794-1-2-E4
Repeated Bending: IEC 60794-1-2-E6
Torsion Test: IEC 60794-1-2-E7
Cable bend: IEC 60794-1-2-E11A
Attenuation Coefficient: ITU-T G. 652
Structural Test: IEC-60793-1-20
Environmental Performance
Temperature Cycling: IEC 60794-1-2-F1
Water Penetration: IEC 60794-1-2-F5B
Filing Compound Flow: IEC 60794-1-E14
Structure and Technical Specifications
Fiber Count |
Nominal Diameter (mm) |
Nominal Weight (kg/km) |
Max Fibers per Tube |
No. of (Tubes+fillers) |
Allowable Tensile Load (N) |
Allowable Crush Resistance (N/100mm) |
Short Term |
Long Term |
Short Term |
Long Term |
2 ~ 30 |
15.5 |
407 |
6 |
5 |
10000 |
4000 |
5000 |
3000 |
32 ~ 36 |
16.0 |
437 |
6 |
6 |
10000 |
4000 |
5000 |
3000 |
38 ~ 60 |
16.6 |
463 |
12 |
5 |
10000 |
4000 |
5000 |
3000 |
62 ~ 72 |
17.2 |
499 |
12 |
6 |
10000 |
4000 |
5000 |
3000 |
>72 |
Available upon customer's request |
Note: 1. According to different applications, GYTA333, GYTS33, GYTS333, GYTY53+33, GYTY53+333, GYTA53+33, GYTA53+333 can provided.
2. S pecial cable structure can be designed and manufactured on customer's request. |